Language

Ideal Solution for First-line Verification

The desktop device Regula 4115 has a set of white, IR and UV light sources of different wavelengths. Light sources for different examination modes are activated with control buttons located on the top panel of the device. The device is equipped with a built-in camera displaying an image on the 7-inch screen.

A passport or currency database can be optionally integrated into the device for visual comparison of examined objects with reference images.

The delivery set includes a modified 10x magnifier, Regula 1003M, with two white light sources that can be used for additional visual checks.

The model Regula 4115.01 is supplied both with Regula 1003M and a spectral luminescent magnifier, Regula 4127, intended for advanced document verification.

Intended Objects for Examination

Passports
ID cards
Passport stamps
Banknotes
Signatures and handwritten notes
Vehicle registration certificates
Driver’s licenses
Revenue stamps

Highlighted Features

Varied light sources

Regula 4115 has white, ultraviolet and infrared light sources of different types and different wavelengths.

Large documents

Examines documents up to 210x300 mm — A4 paper size.

Extra equipment

10x magnifier Regula 1003M with two white light sources and a spectral luminescent magnifier Regula 4127 for advanced document verification.

Magnetic properties

Detection of security features with magnetic properties.

Integrated database

A passport or currency database can be optionally integrated into the device for visual comparison of examined objects with reference images.

Rapid light changing

Automatic switching between selected light sources.

IR and UV at a time

Simultaneous activation of two light sources: IR 830 nm for examination on the monitor screen, and UV 365 nm for visual examination.

M-mark visualization

Alternate switching between IR 830 nm and IR 950 nm light sources for M-mark visualization.

Precise measurements

Automatic measurement of the banknote area (residual area).

Download brochure

Examples of Examination

Document examination in different light sources and operation modes

Efficient Solution for a Variety of Sectors

Regula in Security printing industry
Security printing industry
Regula in Banks & financial agencies
Banks & financial agencies
Regula in Border control & immigration services
Border control & immigration services

One-Stop Shop for Hardware, Software and Knowledge

face recognition with Regula face sdk

Specialized Training

Training courses on document and banknote authentication

Read more
face recognition with Regula face sdk

Information Reference Systems

Databases of travel documents, banknotes, driver's licenses and vehicle registration certificates

Read more

Specifications

Does not constitute а public offer

BELOW THERE ARE PARAMETERS FOR THE FLAGSHIP MODEL 4115.01. FOR OTHER MODELS IN THE SERIES, SEE FULL TECHNICAL SPECIFICATIONS.

Light sources

White

incident, oblique, transmitted

Ultraviolet

365 nm

Infrared

- incident: 830, 950 nm
- oblique 880 nm
- transmitted 880 nm

Image capture

Video sensor

- CMOS, 2MP
- frame size 1600×1200 pixels
- field of view — 155x90 mm

Magnification

1x and 2x for 7-inch screen

General parameters

Detector of security features with magnetic properties

Maximum document size

210x300 (A4)

Dimensions

280×185×295 / 200 mm

Weight

3 kg

Power supply voltage

12 V

Delivery set

Magnifier Regula 1003M

Passport / Currency database on micro SD

optionally

Clamping plate

optionally

Spectral luminescent magnifier Regula 4127

supplied only with the model Regula 4115.01

Spectral luminescent magnifier Regula 4127

Light sources

- white: incident, oblique (2 light sources)
- ultraviolet 365 nm
- infrared: incident (830, 950 nm), oblique 870 nm (2 light sources), high-intensity incident 980 nm
- high-intensity incident cyan 505 nm

Video sensor

- CMOS, 2 Mp
- frame size — 1600×1200 pixels
- field of view ― 10×5.6 and 5×2.8 mm
- digital magnification — 2x (without quality loss)
- on-screen magnification for 7-inch screen — 16x and 32x

Available models

  • Regula 4115
  • Regula 4115.01

Full Specification Regula 4115

Download
Selection of currency, denomination, year of issue in the database
Selection of currency, denomination, year of issue in the database
Currency database. Reference banknote in white incident light
Examined banknote in white incident light
Fragment of the examined banknote in white incident light. 2x magnification on the monitor
Currency database. Reference banknote in ultraviolet light (365 nm)
Examined banknote in ultraviolet light (365 nm)
Fragment of the examined banknote in ultraviolet light (365 nm). 2x magnification on the monitor
Currency database. Reference banknote in infrared incident light (830 nm)
Examined banknote in infrared incident light (830 nm)
Fragment of the examined banknote in infrared incident light (830 nm). 2x magnification on the monitor
Currency database. Reference banknote in white transmitted light
Examined banknote in white transmitted light
Fragment of the examined banknote in white transmitted light. 2x magnification on the monitor
Automatic measurement of the banknote area (residual area)
Automatic measurement of the banknote area (residual area)

Talk to an Expert

Thank you for your message!

We’ve received your message. One of our colleagues will get back in touch with you soon. Have a great day!

On our website, we use cookies to collect technical information. In particular, we process the IP address of your location to personalize the content of the site

Cookie Policy rules