Language

Remote Examination of Security Documents

Regula 88XX captures images of documents in different light sources at a super high resolution (up to 4380 ppi in the top-of-the-range model) with one single click.

Regula High Resolution Scanner software sends obtained images and the information about image capture parameters to a remote forensic expert for the in-depth examination. As a result, a forensic expert will decide on the validity of a particular document by examining the digitized document with the possibility to zoom in its fragments.

Revealed counterfeits or rare documents can be digitized and added to the Information Reference System for further use at border checkpoints*.

*Regula IRS is purchased separately, for adding your samples in Information Reference System you also require Regula Document Builder software.

Intended Objects for Examination

Passports
Passports
ID Cards
Visas
Passport stamps
Passport stamps
Banknotes
Banknotes
Signatures and handwritten notes
Signatures and handwritten notes
Vehicle registration certificates
Vehicle registration certificates
Driver’s licenses
Driver’s licenses
Revenue stamps
Revenue stamps
Art and collectibles

Highlighted Features

400 Mp camera

Available in Regula 88100. Other models come with cameras from 80 to 187 Mp.

Varied light sources

Depending on the model Regula 88XX is equipped with from 10 up to 16 types of light sources: incident, oblique, coaxial, transmitted and high-intensity infrared of different spectral ranges.

190×127 mm field of view

Get an image of a page spread for convenient examination.

Remote forensic expertise

Send super high resolution images together with metadata to a remote forensic expert for in-depth examination.

Information Reference Systems

Additionally you can use Regula IRS which contains document templates with the detailed description of security features. With the help of Regula Document Builder software you can add samples of valid or forged documents.

Module for reading RFID chips

Read data from RFID chips for cross-comparison of text and graphic data.

Download Brochure

Examples of Examination

Document examination in different light sources and operation modes

Efficient Solution for a Variety of Sectors

Regula in Security printing industry
Security printing industry
Regula in Banks & financial agencies
Banks & financial agencies
Regula in Border control & immigration services
Border control & immigration services

One-Stop Shop for Hardware, Software and Knowledge

ID verification sdk by Regula

Specialized Training

Training courses on document and banknote authentication

Read more
ID verification sdk by Regula

Information Reference Systems

Databases of travel documents, banknotes, driver's licenses and vehicle registration certificates

Read more

Specifications

Does not constitute а public offer

Light sources 8850F 8850M 8880 88100

White incident

White oblique (2 light sources)

White oblique for hologram examination (45 light sources)

White coaxial

White transmitted

Ultraviolet 254±10 nm

Ultraviolet 313±10 nm

Ultraviolet 365±10 nm

Infrared incident 720±20 nm

Infrared incident 860±20 nm

Infrared incident 940±20 nm

infrared oblique 870±20 nm (2 light sources)

Infrared transmitted 860±20 nm

Infrared transmitted 940±20 nm

Infrared high-intensity convertible 800─1100 nm

High-intensity incident cyan 505±20 nm

Functionality 8850F 8850M 8880 88100

Camera, Mp, not less

80

80

187

400

Field of view, mm, maximum

188×141

188×141 and 135×101.5

190×127 and 135×90

188×141 and 135×101,5

Resolution, ppi, not less

1386

1386 and 1952

2237 and 3401

3140 and 4380

Reader of radio frequency identification devices (RFID)

General parameters

Connection interface

USB 3.0

Dimensions

- Regula 8850F, 8850M, 8880 — 540×480×480 mm
- Regula 88100 — 660×525×550 mm

Weight

- Regula 8850F, 8850M, 8880 — 40 kg
- Regula 88100 — 50 kg

Power supply

110-240 V; 50-60 Hz; 2-5 A

Delivery set

Regula High Resolution Scanner software

Full Specification Regula 88XX

Download

Regula High Resolution Scanner Software

Download

Models available for order:

  • Regula 88100
  • Regula 8880
  • Regula 8850M
  • Regula 8850F
Incident white
Oblique white
Ultraviolet 365 nm
Ultraviolet 313 nm
Incident infrared 870 nm
Oblique infrared 870 nm
High-intensity convertible infrared 980 nm
Incident white
Oblique white
Transmitted white
Incident infrared 870 nm
Oblique infrared 870 nm
Transmitted infrared 870 nm
Ultraviolet 365 nm
Ultraviolet 254 nm
High-intensity incident cyan 505 nm

Talk to an Expert

Thank you for your message!

We’ve received your message. One of our colleagues will get back in touch with you soon. Have a great day!

On our website, we use cookies to collect technical information. In particular, we process the IP address of your location to personalize the content of the site

Cookie Policy rules